Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

General

Showing 11

Maybe it's time for Bentley to ditch AutoCAD versions of ProStructures and focus efforts on Microstation based version

Hard decisions must be made. The Opensuite (OpenRoads, Opensite, OpenBridge, OpenBuildings) that doesn't have AutoCAD versions, are e evolving much faster than ProStructures. Perhaps thats why we don’t have until now a OpenStructures, no? Legacy i...
over 1 year ago in General 2 Needs review

Active live bill of reinforcing

We need a active live bill of reinforcing in Prostructures just like how PowerRebar had. We do not show our reinforcing in a table form with leg lengths so the schedule generator tool is useless for us. We need to see how a bar looks with the corr...
9 months ago in General 0 Needs review

Prosteel export connections to IDEA statica

Please consider making an option to export created connections to IDEA statica program. Many other programs have this option, including Revit, Advance steel, Tekla
12 months ago in General 0 Needs review

Search Parts - Automatic Scan Model

Why doesn't launching the Search Part utility automatically scan the model? It is a redundant step in the search process. Users cannot create a search definition without scanning the model.
4 months ago in General 1 Needs review

GenerativeComponemts nodes

It would be good to support generativecomponents. This should make automation much more powerful in prostructures.
almost 2 years ago in General 0 Needs review

Make software independent of system settings for "Decimal separator" (and others)

for example the "Schedule Generator" tool crashes when decimal separator is not set to '.' (dot) This is really unacceptable. If any other software requires a different setting to not-crash then it's simply impossible to have them both run on the ...
over 1 year ago in General 0 Needs review

Partlist Element data in Explorer Window or Properties dialog

Currently, custom parts developed as Partlist Elements in ProStructures cannot be reported on using Explorer - Items window. Explorer is a powerful tool that allows you to extract In Drawing Reports of model data in a simple and efficient manner. ...
7 months ago in General 0 Needs review

Ability extract Partlist for Reference DGN files

Currently, ProStrucutres cannot export Partlist files for referenced DGN files. Hence, it is not possible to extract unique configuration of BOM's from multiple DGN files.
7 months ago in General 0 Needs review

Edit the Rebar Code within ProStructures.

Currently, to customize something in the rebar code one needs to manually edit the RebarCode_xxxx.xml file from the Program Files directory which consumes too much time. If ProStructures have the ability to edit the rebar code within the applicati...
over 1 year ago in General 0 Needs review

Three washers for MTH clamp connections

In most special connections with external parts , norm give us instructions to use additional washer. It happen for example in MTH clamp connections. (Nova grip MTH)
over 1 year ago in General 0 Needs review